Max Zs is the maximum permissible values of earth fault loop impedance (Ω), some maximum Zs values are listed in BS 7671, the maximum earth loop impedance values listed in the Zs tables are used to compare against the actual measured earth loop impedance values to ensure compliance with BS 7671. So now consider phase A in our 277/480V wye system. We can plot the voltage relative to our earth reference as a function of time, and get a graph, ideally a nice sine curve. At time zero the voltage will be zero. At 1/240 of a second, the voltage will be +392V (277V * 1.414, the square root of 2). Then at 2/240 second the voltage will again be zero. At 3/240 of a second the voltage will be -392V, and at 4/240 second (1/60 second) the voltage will again be zero. This cycle will repeat. The Cmin factor is applied to the voltage to earth (Uo), so if the voltage is 230 the calculation would be 230×0.95 = 218.5 volts. How accurate is the 3kA value, and is that subject to cut off characteristics from upstream devices

All SPDs work by diverting surge currents to earth to reduce the over-voltage to a level that will not damage the components of the system or equipment connected to it. There are three types of surge protection devices: Type 1 To see how AC voltages add up, we have to remember that the AC voltage is a form of average, and we have to look at the instantaneous values, get an instantaneous sum, and take the average of that. Let through energy is a bit problematic for breakers - a fuse gets faster as the fault current rises, and tends towards a constant let- through energy (I squared r times time, but the resistance r is a fixed parameter of the fuse, as is the weight of metal to be raised to melting point to start it breaking)The Institution of Engineering and Technology (IET) Wiring Regulations (BS 7671) has updated its guidance on surge protection devices (SPD) in successive editions. Current 18 th Edition, released in July 2018 and applicable from January 2019, outlined revised guidance advice for contractors, and new criteria for where these devices should be installed. Which leaves you with the lighting circuits - how far down the cable do you need to go, if the 3kA value is present at the DB, using 1.5mm2 conductors before you are safe again - not far I suspect. This is developed in Note 2 to regulation 536.4.203, which states that ‘ If an assembly deviates from its original manufacturer’s instructions, or includes components not included in the original verification, the person introducing the deviation becomes the original manufacturer with the corresponding obligations’. I suspect that this latter condition will not be a problem in this case as this is for a specific fault current below the maximum that is already within the scope of the existing installation, so it will be sufficient to do a calculation for the increased let through energy with the new short circuit current. Now imagine another point in the system, also connected to phase A. If we measure the voltage at this point, we will get the exact same curve. Finally, try to measure the voltage between these two locations. If you look at each instant in time, the voltage _difference_ will be zero. The average of zero is still zero. Net result is that if you measure the voltage between two points, both phase A, you will get zero volts, as expected.

The reference calibration temperature for types B,Cor D shall be 30 'Cand for types 1, 2,3 and 4 shall be either The 17th edition of the IET wiring regulations amendment 3 introduced the Cmin (0.95) factor which reduced the old maximum zs values to allow for the fluctuation of the voltage. Virtually every building in the UK, regardless of use, will contain electrical devices and equipment, which are central to everyday living and convenience. However, transient over-voltages, also known as power surges, can seriously damage these pieces of equipment. Damaged equipment not only incurs the expense of repair or replacement but also further, long term costs such as lost data if storage devices are damaged. New Requirements

When purchasing a consumer unit or distribution board, the manufacturer’s instructions will state which devices can be used in the unit – and don’t forget according to BS 7671 (regulation 510.3) there is an obligation on designers and installers to follow the manufacturer’s instructions when selecting and erecting equipment. The last bit is to ask ‘how do I calculate the voltage difference between two phases with some other phase angle?’ Clearly this is some function of the amplitude of the phases, and also a function of the phase angle between them. Simplify the question by stating that both phase A and phase W have the same phase to neutral RMS voltage V. Call the phase angle between these two phases T. The voltage between the phases is then given by V * 2 * sin(T/2). So for the 180 degree phase difference we get V * 2 * sin(180/2) = V *2 MCB (Miniature Circuit Breaker ( BS 3871 ) is a mechanical device operate automatic operation designed to connect and disconnect the electrical circuit in the ordinary and extraordinary situation.Suitable for AC and DC voltage.It mean main function is to protected equipment or circuit from overload and short circuit. should be taken as soon as possible to improve the safety of the installation." would be appropriate but maybe your not talking about the LoadMaster